Инструменти за потребители

Инструменти за сайта


en:electrical_connections

Разлики

Тук са показани разликите между избраната и текущата версия на страницата.

Препратка към сравнението на версиите

Both sides previous revisionПредходна версия
en:electrical_connections [2023/05/07 21:01] siyanaen:electrical_connections [2023/05/08 11:34] (текуща) svilen
Ред 1: Ред 1:
 =====Electrical connection===== =====Electrical connection=====
-The controller CW01R66 consists of two circuit boards connected by a ribbon cable. The control board with a display, which is an inseparable part of the board, is intended to be placed on the front panel of the dashboard. The coin mechanism and all buttons are connected to it. The relay board could be placed at the base of the board as it is connected to the power supply and the control signals.+The controller CW01R66 consists of two circuit boards connected by a ribbon cable. The control board with a display, which is an inseparable part of the board, is intended to be placed on the front panel. The coin mechanism and all buttons are connected to it. The relay board could be placed at the base of the case as it is connected to the power supply and the control signals.
 {{ :wiki:cw01r66_electrical_diagram.jpg?nolink |}} {{ :wiki:cw01r66_electrical_diagram.jpg?nolink |}}
  
Ред 8: Ред 8:
  
 ====Control signals==== ====Control signals====
-For control of the executive mechanisms such as pumps, valves, dispensers, and heaters are provided 6 relays as the contact circuit of each relay is shown on the labels. For each program could be made a random combination of active relays.+For control of the executive mechanisms such as pumps, valves, dispensers, and heaters are provided 6 relays and the contact circuit of each relay is connected to the terminals. For each program could be made a arbitarty combination of active relays.
 {{ ::cw01r66_relays_diagram.png?nolink |}} {{ ::cw01r66_relays_diagram.png?nolink |}}
 The maximum permissible load on each relay is 250V 5A. The maximum permissible load on each relay is 250V 5A.
  
-**Tip:** To reduce the number of connected cables, power can be supplied to each pin and so when the free edge output is activated a control voltage will be directly available.+**Tip:** To reduce the number of connected cables, a supply voltage can be provided to each relay and when it is activated a control voltage will be directly available.
 {{ :cw01r66_relays_common_power.png?nolink |}} {{ :cw01r66_relays_common_power.png?nolink |}}
  
 ====Coin mechanism==== ====Coin mechanism====
-The communication with the coin mechanism is done over the standard parallel interface, using connectors with 2 x 5 pins. You can make a consultation with the documents of the coin mechanism to check if it matches the drawing.+The communication with the coin mechanism is done over the standard parallel interface, using connectors with 2 x 5 pins. You can reference the documents of the coin mechanism to check if it matches the drawing.
 {{ ::cw01r66_coins_acceptor_pinout.png?nolink |}} {{ ::cw01r66_coins_acceptor_pinout.png?nolink |}}
 ^ outlet ^ name  ^ description ^ ^ outlet ^ name  ^ description ^
Ред 24: Ред 24:
 | 4 | COIN 6 | Impulse for a coin with code 6 | | 4 | COIN 6 | Impulse for a coin with code 6 |
 | 5 | RET | Returned coin / Impulse for a coin with code 7 | | 5 | RET | Returned coin / Impulse for a coin with code 7 |
-| 6 | INH | Prohibition for acceptance of coin |+| 6 | INH | Inhibit of coins acceptance |
 | 7 | COIN 1 | Impulse for a coin with code 1 | | 7 | COIN 1 | Impulse for a coin with code 1 |
 | 8 | COIN 2 | Impulse for a coin with code 2 | | 8 | COIN 2 | Impulse for a coin with code 2 |
Ред 30: Ред 30:
 | 10 | COIN 4 | Impulse for a coin with code 4 | | 10 | COIN 4 | Impulse for a coin with code 4 |
 The controller is capable of recognizing the listed signals: The controller is capable of recognizing the listed signals:
-  * single pulse for each of the 6 canals- this is how are maintained up to 6 different types of coins +  * single pulse for each of the 6 channels - this is how are maintained up to 6 different types of coins 
-  * a sequence of pulses; for instance 1 pulse - 50 st., 2 pulse - 1 lev, 4 pulse - 2 levs +  * a sequence of pulses; for instance 1 pulse - 50 cents, 2 pulses - 1 euro, 4 pulses - 2 euros 
-  * pulses with different duration; for instance 100 ms. - 50 st., 200 ms. - 1 lev, 300 мс. - 2 levs +  * pulses with different duration; for instance 100 ms. - 50 cents, 200 ms. - 1 euro, 300 ms. - 2 euros 
-  * a combination of codes (known as binary); for instance pulse simultaneously 1 and 2 canal- this is how are maintained more than 16 different coins +  * a combination of codes (known as binary); for instance pulse simultaneously to 1 and 2 channel in this way can be maintained up to 16 different coins.
  
 ====Buttons==== ====Buttons====
 The connection of the buttons is carried out with 6 signal lines and common ground. The connection of normally open and normally closed buttons, as well as keys is allowed.\\ The connection of the buttons is carried out with 6 signal lines and common ground. The connection of normally open and normally closed buttons, as well as keys is allowed.\\
 If more buttons are necessary: If more buttons are necessary:
- By using separation diodes it is possible for one button to control several signal lines. In this way, it is possible to connect up to 16 buttons for programs and key operators.+ By using separation diodes it is possible for one button to control several signal lines. In this way, it is possible to connect up to 16 buttons for programs and operator'key.
 {{ ::cw01r66_buttons_diagram.png?nolink |}} {{ ::cw01r66_buttons_diagram.png?nolink |}}
-====Complete scheme sample ====+====Complete scheme example ====
 This is a scheme of a built carwash with 4 programs. This is a scheme of a built carwash with 4 programs.
 {{ ::cw01r66_4programs_circuit.png?direct&800 |}} {{ ::cw01r66_4programs_circuit.png?direct&800 |}}
-The  following controlling signs are used:+The  following controlling signals are used:
   * Relay 1 - main valve for water release   * Relay 1 - main valve for water release
   * Relay 2 - compressor for high pressure   * Relay 2 - compressor for high pressure
Ред 49: Ред 49:
   * Relay 4 - wax dispenser   * Relay 4 - wax dispenser
 The following settings for the programs need to be made for the  controller The following settings for the programs need to be made for the  controller
-^ N ^ Program ^ outlet ^+^ N ^ Program ^ relay ^
 | 1 | Water jet | 1 + 2 | | 1 | Water jet | 1 + 2 |
-| 2 | Detergent - high pressure | 1 + 3 | +| 2 | Detergent - low pressure | 1 + 3 | 
-| 3 | Detergent - low pressure (foam)| 1 + 2 + 3 |+| 3 | Detergent - high pressure (foam)| 1 + 2 + 3 |
 | 4 | Wax | 1 + 4 | | 4 | Wax | 1 + 4 |
  
  
en/electrical_connections.1683493287.txt.gz · Последна промяна: 2023/05/07 21:01 от siyana