Съдържание
Electrical connection
The controller CW01R66 consists of two circuit boards connected by a ribbon cable. The control board with a display, which is an inseparable part of the board, is intended to be placed on the front panel. The coin mechanism and all buttons are connected to it. The relay board could be placed at the base of the case as it is connected to the power supply and the control signals.
Power supply
The controller requires a power supply of 12V 0.5A. It provides the function of the display, the control relays, and the coin mechanism.
Control signals
For control of the executive mechanisms such as pumps, valves, dispensers, and heaters are provided 6 relays and the contact circuit of each relay is connected to the terminals. For each program could be made a arbitarty combination of active relays. The maximum permissible load on each relay is 250V 5A.
Tip: To reduce the number of connected cables, a supply voltage can be provided to each relay and when it is activated a control voltage will be directly available.
Coin mechanism
The communication with the coin mechanism is done over the standard parallel interface, using connectors with 2 x 5 pins. You can reference the documents of the coin mechanism to check if it matches the drawing.
outlet | name | description |
---|---|---|
1 | GND | Common ground |
2 | V12 | Power supply 12V |
3 | COIN 5 | Impulse for a coin with code 5 |
4 | COIN 6 | Impulse for a coin with code 6 |
5 | RET | Returned coin / Impulse for a coin with code 7 |
6 | INH | Inhibit of coins acceptance |
7 | COIN 1 | Impulse for a coin with code 1 |
8 | COIN 2 | Impulse for a coin with code 2 |
9 | COIN 3 | Impulse for a coin with code 3 |
10 | COIN 4 | Impulse for a coin with code 4 |
The controller is capable of recognizing the listed signals:
- single pulse for each of the 6 channels - this is how are maintained up to 6 different types of coins
- a sequence of pulses; for instance 1 pulse - 50 cents, 2 pulses - 1 euro, 4 pulses - 2 euros
- pulses with different duration; for instance 100 ms. - 50 cents, 200 ms. - 1 euro, 300 ms. - 2 euros
- a combination of codes (known as binary); for instance pulse simultaneously to 1 and 2 channel - in this way can be maintained up to 16 different coins.
Buttons
The connection of the buttons is carried out with 6 signal lines and common ground. The connection of normally open and normally closed buttons, as well as keys is allowed.
If more buttons are necessary:
By using separation diodes it is possible for one button to control several signal lines. In this way, it is possible to connect up to 16 buttons for programs and operator's key.
Complete scheme example
This is a scheme of a built carwash with 4 programs. The following controlling signals are used:
- Relay 1 - main valve for water release
- Relay 2 - compressor for high pressure
- Relay 3 - detergent dispenser
- Relay 4 - wax dispenser
The following settings for the programs need to be made for the controller
N | Program | relay |
---|---|---|
1 | Water jet | 1 + 2 |
2 | Detergent - low pressure | 1 + 3 |
3 | Detergent - high pressure (foam) | 1 + 2 + 3 |
4 | Wax | 1 + 4 |